Filter Results By:

Products

Applications

Manufacturers

Volt Meters

Measure differences in voltage.


Showing results: 46 - 60 of 73 items found.

  • 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer

    Extech EX623 - Extech Instruments Corporation

    This TRMS AC/DC Clamp Meter has dual thermocouple inputs for T1, T2, T1-T2 Differential Temperature measurement plus a built-in Infrared Thermometer with laser pointer for locating hot spots and NCV Detector. Additional features include: DC micro-amp function for flame rod measurements, Diode open circuit voltage of 2.8 Volt, Data Hold plus fast Peak Hold for capturing current surges at motor startup, and capacitance measurement to 40mF. Comes complete with test leads, 9 Volt battery, two Type K bead wire Temperature probes and carrying case.

  • AC Power Measurement and Logging

    WattNode® Logger for LonWorks® - Continental Control Systems LLC

    The WattNode Logger is a kilowatt hour (kWh) energy meter that communicates on a LonWorks network, and can log 24,000+ measurement records in non-volatile memory. The WattNode Logger measures 1, 2, or 3 phases with voltages from 120 to 600 volts alternating current (Vac) and 5 to 6,000 amps in delta (phase to phase) and wye (phase to neutral) configurations.

  • Resistance System Kit

    PMK-151 - Prostat Corporation

    The PMK-151 Basic Measurement Kit has all the functionality of the PMK-152, but adds computer downloading capabilities. It contains all the instruments you need to take a variety of resistance measurements.The PMK-151 includes Prostat's PRS-801 Resistance Set with modified 5 pound conductive rubber electrodes, the PRS-801 wide range resistance meter, and Prostat PRS-801 Connectivity software for computer data downloading. You can take measurements at 10 and 100 volts with accuracy within ±5%.

  • Field Strength Meter

    FIM-71 VHF - Potomac Instruments, Inc.

    The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • Field Strength Meter

    FIM-72A UHF - Potomac Instruments, Inc.

    The Model FIM-72A is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-72A is suitable for practically all types of RF emission measurements in the 450 MHz to 960 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and meter dynamic range of either 20 dB or 60 dB. A dc analog voltage, proportional to meter indication, is provided for driving a chart recorder or similar device. A leveled output from the calibrating generator is available for measuring cable insertion loss, filter response, amplifier gain, VSWR, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.

  • 12 Function True RMS Professional MultiMeter + InfraRed Thermometer

    Extech EX470A - Extech Instruments Corporation

    The Extech EX470A True RMS Multimeter and Infrared Thermometer with Capacitance, Frequency, and Duty Cycle Measurements and 2 K-Type Remote Probes is the perfect meter for HVAC or plant maintenance. The IR thermometer measures the surface temperature from -4 to 518 °F (-20 to 270 °C) without contact. The built-in laser pointer centers the measuring area. Multimeter functions include AC and DC Voltage to 600 Volt, AC and DC current to 10A, resistance to 40MOhm, continuity and diode test. Also includes Type K thermometer for contact or air temperature measurements from -4 to 1832 °F (-20 to 750 °C). Advanced functions include Capacitance, Frequency and Duty Cycle. The meter comes complete with test leads, Type K temperature probe, 9 Volt battery, protective holster, adjustable tilt stand and Velcro hanging strap.

  • Ionization Test Set

    PFK-105 - Prostat Corporation

    - Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included

  • Digital Multimeter

    MM-2 - Dwyer Instruments Inc.

    Our compact, low cost Model MM-2 Digital Multimeter with True RMS is ideal for general electrical testing and troubleshooting. This full function multimeter measures DC voltage to 1000 V and AC voltage to 750 V, DC and AC current to 10 A and resistance to 400 Ohms. In addition to volts, amps and ohms, this meter includes audible continuity, diode, LED and transistor hFE tests. The rotary switch allows you to select from any of the functions quickly and easily.

  • 6/8/12 Volt 0-1000 Amp Heavy-Duty Variable Carbon Pile Load Tester

    7136R - Associated Equipment Corp.

    • High-volume testing and fleet use• Tests 6/12 Volt batteries• 1000 Amp load; tests batteries up to 2000 cold cranking amps• Built in LCD Digital Voltmeter and LCD Digital Amp Meter• Cools with high RPM fan for continuous battery testing• High resolution carbon pile assembly for smoother operation and longer life• Optional Model 6038C for added mobility with convenient heavy-duty cart with wheels• RoHS and CE Compliant• Made in USA of US and Global Components

  • 500 AMP Carbon Pile Load Tester

    710 - Electronic Specialties Inc.

    The #710 will perform variable load testing on 12 volt batteries rated as high as 1000 Cold Cranking Amps. Use this battery tester to simulate actual cranking loads. Also tests alternator charging voltage and relative starter current draw. The #710 features large dual meters to display the battery voltage and load current simultaneously, during the test.

  • Surface DC Voltmeter

    SVM2 - Alpha Lab, Inc.

    The SVM2 has high sensitivity (resolution), and can detect even a 1 volt charge anywhere within its full range of +29,999 to -29,999 volts. Thus it is easy to measure whether a given process is increasing or decreasing the static electricity present, even if the increase or decrease is by a tiny fraction. The meter reads the actual static signal, but it also captures and stores the highest positive and highest negative signals that were experienced since the last time that the "Reset" button was pressed. These peak + and can be displayed at any later time. The peak function has a "window" time of 0.005 seconds (which is much faster than the display) so even very quick peaks are captured and stored. There is also a user-settable alarm. The alarm will sound if the signal (whether + or -) ever exceeds the value set by the user for at least 0.005 seconds. The alarm can be reset or muted at any time.

  • DC - 400 MHz PC-Based Timer Interval Analyzer

    Guide Technology, Inc.

    GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.

  • Telemetry

    ESI Technology Ltd

    Single channel system, offering wireless transfer of a single analogue signal, either 4-20mA or DC voltage. Mixed signal radio telemetry solution. Analogue I/O: 2x 2-40mA or DC Voltage. Digital I/O: 2x volt free or optional pulse counting required. Multi-channel radio telemetry system, 4 Analogue and 8 digital inputs. Significant signal connectivity and data transfer in a standard package.12 I/O channels allow greater signal monitoring capability SENSOR LINK Compact wireless telemetry link for any strain gauge sensor or RTD. Transmissions distance 1 to 300 meters. Licence free radio operation.16 bit ADC resolution.

  • High Resistance Meter

    HR2 - Alpha Lab, Inc.

    The Model HR2 meter measures resistance in nine ranges from 1 ohm to 1.9999 Tera ohms (1.9999x1012 ohms), and conductance in a single range of 0.00 to 199.99 pS (pico siemens, or pico mhos), all at low voltage of < 2 volts across the sample. Basic accuracy is +/- 2% of reading +/- 1 count. For resistance higher than 1.9999 Tera ohms, the conductance range can be used to measure conductance down to 0.01 pS (100 T ohms). The meter has a conductance range because samples with simultaneously high resistance and high capacitance settle faster to their final value on conductance (usually under one second), than on resistance (several seconds), and conductance is also capable of detecting higher resistance than the resistance ranges can. Note that resistance in units of T ohms is the inverse of conductance in pS, so that the resistance can be calculated from the conductance. For example, 100 pS is 0.01 T ohm (10 G ohm), and the highest readable conductance of 199.99 pS is essentially 5 G ohms.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.